HP CLJ M6030, 6040 Causes and solution for fuser delivery delay jams

Author: Metrofuser Tech Support Reference Number: AA-05443 Views: 4527 Created: 06-12-2012 05:30 pm Last Updated: 06-12-2012 05:30 pm 0 Rating/ Voters

    1       Cause :   The loop sensor lever is not set correctly

              solution :   Check the loop sensor lever and place it in the correct position.

    2        Cause:    The spring of the fuser delivery media feed sensor lever is unhooked.

               Solution:   Check the spring of the fuser and right door sensor levers and place it in the correct position

    3        Cause:     The fuser delivery media feed sensor lever damaged.

               Solution:   Replaced the fuser or right door.

    4        Cause:     Poor contact of the fuser delivery media feed sensor connector.

               Solution:  Reconnect the connector of the fuser delivery media feed sensor(J1945), Intermediate ( J1950, J1919 ) and the dc controller PCA ( J108)

    5         Cause:     The fuser delivery media feed sensor is defective.

               Solution:  Check the fuser delivery media feed sensor by the sensor monitor mode. If the sensor is defective, replace the right door.

     6         Cause:    Poor contact of the fuser motor connector

                Solution:    Reconnect the connectors of the fuser motor ( J1711 ), intermediate ( 1720) and the dc controller PCA (105 ).

      7        Cause:      The fuser motor is defective.  

                 Solution:   Execute the fuser motor driving test in the actuator drive mode. If the motor defective, replace the fuser motor.